Timeguard TX2440 40A 30mA Solid Neutral RCBO B Curve 6kA, 30mA Type A, Uni-Directional

SKU TX2440
Original price £11.16 - Original price £11.16
Original price
£11.16 inc VAT £9.30 exc VAT
£11.16 - £11.16
Current price £11.16 inc VAT £9.30 exc VAT inc VAT £9.30 exc VAT

Estimated delivery time: Estimated delivery tomorrow*

Description

Timeguard TX2440 40A 30mA Type A RCBO – B-Curve, 6kA

The Timeguard TX2440 is a 40A, 30mA Type A RCBO with a B-curve overcurrent characteristic and 6kA breaking capacity. It combines overload, short-circuit and residual-current protection for an individual circuit in a compatible Timeguard TX series consumer unit.

This is the solid-neutral, unidirectional version. Those details matter when ordering a replacement: matching the current rating and physical size alone does not establish that another RCBO is interchangeable.

Check the neutral arrangement and power-flow direction

With a solid neutral, the neutral remains connected when the protected line pole opens. This differs from a switched-neutral device, which also disconnects the neutral.

Unidirectional operation means the RCBO must be connected according to the manufacturer’s supply and load markings. It must not be selected for a circuit requiring bidirectional power flow.

For a new installation or replacement, the electrician must confirm consumer unit compatibility, cable protection, connected equipment and the required isolation arrangement.

What the protection ratings mean

The 40A rating relates to the circuit’s overcurrent protection. The 30mA rating is the rated residual operating current of the earth-leakage protection.

Type A residual-current protection responds to sinusoidal AC and pulsating DC residual currents. B-curve describes the separate overcurrent operating characteristic.

Compact size with clearly specified terminals

The single-module housing measures 18mm wide × 85mm high × 73mm deep and mounts onto a 35mm DIN rail.

Top terminals accept conductors up to 10mm², with a specified tightening torque of 1.2Nm. Bottom terminals accept up to 25mm², with a tightening torque of 2.5Nm. Terminal blanking plates help prevent incorrect cable or busbar insertion.

A test button and contact position indicator are included. The device can also be removed without removing the busbar once the assembly has been safely isolated.

Timeguard provides a five-year guarantee, subject to its applicable terms. Manufacturer compatibility is limited to Timeguard TX series consumer units.

Specification
  • Range - TX circuit protection
  • Manufacturer Product Code - TX2440
  • Product Type - RCBO
  • Rated Current - 40A
  • Rated Residual Operating Current - 30mA
  • Residual-Current Classification - Type A
  • Overcurrent Tripping Characteristic - B-curve
  • Short-Circuit Breaking Capacity - 6kA
  • Energy Limiting Class - Class 3, as listed in the manufacturer’s brochure
  • Pole Arrangement - Single pole with solid neutral
  • Neutral Switching - Unswitched
  • Directionality - Unidirectional
  • Protection Functions - Overload, short circuit and residual current / earth leakage
  • Rated Voltage - 240V AC, as listed in the datasheet
  • Rated Frequency - 50/60Hz, as listed in the datasheet
  • Module Width - 1 module
  • Mounting - 35mm DIN rail
  • Maximum Top Terminal Capacity - 10mm²
  • Maximum Bottom Terminal Capacity - 25mm²
  • Top Terminal Tightening Torque - 1.2Nm
  • Bottom Terminal Tightening Torque - 2.5Nm
  • Terminal Feature - Blanking plates to help prevent incorrect cable or busbar insertion
  • Test Button - Included
  • Contact Position Indicator - Included
  • Device Removal - Without removing the busbar
  • Electrical Endurance - 4,000 cycles
  • Mechanical Endurance - 10,000 cycles
  • Dielectric Strength - 2500V
  • Housing Material - PA6
  • Dimensions - 85mm high × 18mm wide × 73mm deep
  • Standards Listed - IEC/BS EN 61009-1 and IEC/BS EN 61543
  • Compatibility - Timeguard TX series consumer units only
  • Manufacturer’s Guarantee - 5 years
FAQ's

How do I check whether TX2440 is the correct replacement?

Check the existing device’s complete code and the consumer unit’s approved-device information. The electrician must also confirm the current rating, residual-current type, tripping curve, neutral arrangement, directionality and circuit requirements.

What is the practical difference between TX2440 and TX2440C?

Their overcurrent tripping characteristics differ. C-curve has a higher instantaneous magnetic operating threshold than B-curve. Changing between them requires a circuit-design check; matching the 40A rating alone is insufficient.

Why would someone choose TX2540 instead?

TX2540 has switched neutral and bidirectional operation, while TX2440 has solid neutral and unidirectional operation. The required choice depends on the circuit’s isolation and power-flow requirements, along with manufacturer-approved compatibility.

Does solid neutral mean the neutral disconnects when the RCBO trips?

No. The protected line pole opens, while the neutral remains connected. The installation’s isolation requirements must therefore be assessed separately.

Can TX2440 be used in a property that has solar panels?

The particular circuit and its possible power flow must be assessed. This device is unidirectional and must not be selected for a circuit requiring reverse or bidirectional power flow. The presence of solar elsewhere in the property does not, by itself, establish suitability.

What do 40A, 30mA and 6kA each mean?

40A is the rated circuit current. 30mA is the rated residual operating current of the earth-leakage protection. 6kA is the rated short-circuit breaking capacity. These figures describe separate characteristics.

Why does it say Type A and B-curve?

Type A describes residual-current detection, including sinusoidal AC and pulsating DC residual currents. B-curve describes the overcurrent operating characteristic.