Timeguard TX2345C 45A 6KA Type C Curve MCB

SKU TX2345C
Original price £2.47 - Original price £2.47
Original price
£2.47 inc VAT £2.06 exc VAT
£2.47 - £2.47
Current price £2.47 inc VAT £2.06 exc VAT inc VAT £2.06 exc VAT

Estimated delivery time: Estimated delivery tomorrow*

Description

The Timeguard TX2345C 45A C-curve MCB provides overload and short-circuit protection for an individual electrical circuit. Designed for Timeguard TX series consumer units, this single-pole miniature circuit breaker combines a 6kA breaking capacity with a compact one-module housing.

It is an option for electricians selecting a protective device for a compatible installation or replacing an existing breaker where the circuit requires 45A C-curve protection.

Why the C-curve characteristic matters

A C-curve MCB has a higher instantaneous magnetic operating threshold than an equivalent B-curve breaker. This can accommodate brief starting currents where the connected equipment and circuit design support its use.

The rated current remains 45A. Choosing C-curve does not increase the circuit’s permitted continuous load. Cable protection, equipment starting characteristics and the fault current needed to achieve the required disconnection time must all be checked.

Terminals designed to help prevent incorrect insertion

The terminal cages incorporate blanking plates that help prevent a cable or busbar from being positioned outside the clamp. Maximum terminal capacity is 25mm², with a manufacturer-specified tightening torque of 2.5Nm.

A contact position indicator provides a visible indication of contact status. The breaker can also be removed without removing the busbar, helping with maintenance once the assembly has been safely isolated.

Specification
  • Range - TX circuit protection
  • Product Code - TX2345C
  • Product Type - Miniature circuit breaker / MCB
  • Rated Current - 45A
  • Tripping Characteristic - C-curve
  • Number of Poles - Single pole
  • Rated Voltage - 240V AC
  • Short-Circuit Breaking Capacity - 6kA / 6000A
  • Energy Limiting Class - Class 3
  • Protection Functions - Overload and short circuit
  • Module Width - 1 module
  • Mounting - 35mm DIN rail
  • Maximum Terminal Capacity - 25mm²
  • Terminal Tightening Torque - 2.5Nm
  • Terminal Feature - Blanking plates to help prevent incorrect cable or busbar insertion
  • Contact Position Indicator - Included
  • Device Removal - Without removing the busbar
  • Electrical Endurance - 4,000 cycles
  • Mechanical Endurance - 10,000 cycles
  • Dielectric Strength - 2500V
  • Housing Material - PA6
  • Height - 81mm
  • Width - 18mm
  • Depth - 73mm
  • Standards Listed - IEC/BS EN 60898-1 and IEC/BS EN 60947-2
  • Compatibility - Timeguard TX series consumer units only
  • Manufacturer’s Guarantee - 5 years
FAQ's

What is the Timeguard TX2345C?

It is a 45A C-curve single-pole miniature circuit breaker with a 6kA breaking capacity. It provides overload and short-circuit protection within compatible Timeguard TX consumer units.

Is TX2345C definitely C-curve?

Yes. The manufacturer’s datasheet lists this exact code in its C-curve range. The B-curve bullet on the product page conflicts with the heading and datasheet.

What is the difference between TX2345C and TX2345?

TX2345C is C-curve; TX2345 is B-curve. Both are rated at 45A, but their instantaneous magnetic operating characteristics differ.

What does C-curve mean?

Under BS EN 60898-1, the C-curve instantaneous magnetic operating band is 5–10 times rated current. Its magnetic operating threshold is higher than that of an equivalent B-curve device.

What is that operating band for a 45A C-curve MCB?

It corresponds to 225–450A. This describes short-duration magnetic operation, not a permitted continuous load.

Will it trip immediately if the current exceeds 45A?

Not necessarily. Operating time depends on the magnitude and duration of the overcurrent and the breaker’s time-current characteristic.

Can I replace a 45A B-curve breaker with this model?

Only after an electrician verifies the circuit design. Changing the characteristic affects the fault current needed for rapid operation and may alter whether the required disconnection conditions are met.

Will C-curve stop tripping when equipment starts?

It may be appropriate where verified starting current is the cause and the circuit supports C-curve protection. It will not correct an overload, damaged wiring or faulty equipment.