Skip to content
Over 7000 Products at Incredible Prices!
Over 7000 Products at Incredible Prices!

Ovia OV102100BKCWPC 100W 4000K LED Asymmetric Floodlight With Photocell

SKU OV102100BKCWPC

Use code BF26 at checkout for 5% off.

Original price Β£79.93 - Original price Β£79.93
Original price
Β£79.93 inc VAT Β£66.61 exc VAT
Β£79.93 - Β£79.93
Current price Β£79.93 inc VAT Β£66.61 exc VAT inc VAT Β£66.61 exc VAT
Availability:
31 in stock, ready to be shipped

Estimated delivery time: Next working day

Description

The Ovia OV102100BKCWPC Inceptor Ace 100W LED floodlight with photocell combines powerful illumination with automatic daylight-responsive switching. Delivering 12,000 lumens, this black asymmetric floodlight provides a high-output option for exterior lighting projects where visibility, light distribution and convenient operation matter. Its integrated photocell controls switching as daylight changes, making it useful for customers who want outdoor lighting to operate automatically after dark.Β 

Automatic lighting from dusk to dawn

The included photocell monitors ambient light levels and switches the floodlight according to the surrounding daylight. This helps property owners manage overnight lighting without manually switching the fitting on each evening.

Durable construction for exterior locations

A powder-coated aluminium body and glass front provide a robust construction, finished in black. The fitting carries IP65 ingress protection, guarding against dust and water jets, together with an IK06 impact rating.

Ovia specifies an operating temperature range of βˆ’20Β°C to +40Β°C. These ratings give installers practical information when assessing exposure, environmental conditions and the suitability of a proposed outdoor mounting location.Β 

Adjustable bracket and pre-wired cable included

The supplied adjustable mounting bracket allows the projection angle to be set during installation. This gives electricians flexibility when directing illumination towards an entrance, access route or working area.

A two-metre pre-wired flylead provides cable length for connection to a suitable supply point. For customers replacing an existing outdoor floodlight, checking the cable route, mounting surface and available connection position before installation helps establish what additional materials may be required.

Specification
  • Ingress Protection - IP65
  • Impact Rating (IK) - 06
  • Warranty (Years) - 5
  • Input Voltage & Frequency (V~ / Hz) -Β 220-240 50/60
  • Circuit Wattage (W) - 100
  • Input Current (mA) - 560
  • Inrush Current/Time -Β 30A (500Β΅S)
  • Power FactorΒ >0.9
  • Input Mains Cable -Β 3 x 1mmΒ² H05-RNF (2 metre)
  • Colour Temperature (K) - 4000
  • Colour Render Index (CRI)Β >80
  • Typical Luminous Flux (lm) -Β 12000
  • Efficacy (lm/W) - 120
  • Beam Angle (Β°) -Β 60 x 120
  • LED Lifetime (L70) (Hours) -Β 50000
  • Dimmable - No

Datasheet

Product Dimensions

333 (W) x 420 (H) x 51 (D) (mm)

FAQ's

Does the OV102100BKCWPC include a photocell, and when does it switch on?

Yes. The photocell is included. Ovia states that the floodlight switches on at approximately 10–20 lux and switches off at 30–60 lux. It responds to ambient daylight, providing automatic operation as the surroundings become darker or brighter.

2. Does this floodlight detect movement like a PIR security light?

The included sensor is a photocell, which responds to ambient light levels. Movement-triggered operation requires an appropriate additional control. Ovia confirms that its photocell floodlight range can be used with remote PIR or microwave sensors; your electrician should assess the control arrangement for your installation.

3. What is the benefit of an asymmetric floodlight for a loading bay or yard?

Asymmetric optics direct illumination towards a defined area in front of the fitting. The Inceptor Ace’s 60Β° Γ— 120Β° distribution gives installers a controlled beam pattern to work with when lighting spaces beside buildings or boundaries. Correct positioning and aiming remain important when managing spill light onto neighbouring areas.

4. Is a 100W, 12,000-lumen floodlight enough for my car park or driveway?

Suitability depends on the area’s dimensions, mounting height, obstructions and required ground-level illumination. The 12,000-lumen output is useful for comparison, but it does not establish a fixed coverage area. Ask your installer to assess the layout and calculate suitable positions and quantities using the fitting’s photometric information.

5. Can I dim the light or change it between warm white and cool white?

This model is non-dimmable and has a fixed 4000K cool white colour temperature. The photocell controls automatic switching according to daylight levels. If your project requires adjustable brightness or selectable colour temperature, specify those features when choosing the fitting.

6. Can this floodlight withstand outdoor rain and winter temperatures?

The fitting has IP65 protection against dust and water jets, with a stated operating range of βˆ’20Β°C to +40Β°C. These specifications support its assessment for outdoor use. The installation’s cable connections and accessories also need to suit the exposure conditions at the chosen location.

7. What electrical details should an electrician check before installing several fittings?

Ovia specifies 220–240V AC, 50/60Hz, Class I construction requiring an earth connection, and a 100W circuit rating. The technical sheet lists 30A inrush current for 500 microseconds. Electricians should account for combined running load and driver inrush when designing circuits containing multiple floodlights.

8. How much electricity does the 100W floodlight use?

Calculated from its rated 100W circuit power, the floodlight uses approximately 0.1kWh per operating hour, or 1kWh over ten hours. Multiply that energy use by your electricity unit rate to estimate the operating cost. Daily consumption will depend on how long the photocell keeps the fitting illuminated.