Heatrae 95050471 Sadia Megaflo Eco 250DDD Direct Unvented Hot Water Cylinder

SKU 95050471
Original price £1,500.00 - Original price £1,500.00
Original price
£1,500.00 inc VAT £1,250.00 exc VAT
£1,500.00 - £1,500.00
Current price £1,500.00 inc VAT £1,250.00 exc VAT inc VAT £1,250.00 exc VAT
Availability:
Only 2 left!

Estimated delivery time: Estimated delivery tomorrow*

Description

The Heatrae Sadia Megaflo Eco 250DDD 95050471 is a nominal 250-litre direct unvented hot water cylinder. It heats stored water electrically using three factory-fitted 3kW immersion heaters, providing a combined rating of 9kW at 240V.

As a direct cylinder, it does not depend on a boiler-fed heating coil. It is an option for homes where electricity provides the domestic hot water, subject to an installer confirming the storage capacity, electrical supply and incoming water performance.

What makes the 250DDD different?

The 250DDD has three immersion heaters, compared with the two fitted to the 250DD. This gives it a higher available heating input when all three elements are energised.

The manufacturer publishes an 81-minute heat-up time at 9kW under its test conditions. Actual heating time depends on the starting water temperature, supply voltage, controls and the number of elements operating.

Each immersion heater has its own thermostat and thermal cut-out, providing temperature control and protection against thermostat failure.

Internal expansion helps keep the installation compact

Megaflo Eco accommodates heated-water expansion through an internal air-gap system with a floating baffle. This removes the need for a separate external vessel for the cylinder’s own hot water expansion, helping reduce external components and pipework.

The inner vessel is manufactured from duplex stainless steel, while the immersion heaters use titanium elements. A 60mm layer of polyurethane insulation helps limit heat escaping from the stored water.

Specification
  • Range - Megaflo Eco
  • Model - 250DDD
  • Manufacturer Product Code - 95050471
  • Product Type - Direct unvented hot water storage cylinder
  • Nominal Capacity - 250 litres
  • Heating Method - Electric immersion heaters
  • Number of Immersion Heaters - 3
  • Individual Immersion Rating - 3kW at 240V AC / 2.8kW at 230V AC
  • Combined Rated Heating Input - 9kW at 240V
  • Immersion Element Material - Titanium
  • Inner Cylinder Material - Duplex stainless steel
  • Outer Casing - White pre-coated steel
  • Insulation - Expanded polyurethane foam
  • Nominal Insulation Thickness - 60mm
  • Expansion System - Internal air gap with floating baffle
  • Installation Orientation - Vertical floor mounted
  • Height - 1738mm
  • Body Diameter - 579mm
  • Overall Depth - 600mm, as listed in the manufacturer’s dimensional drawing
  • Empty Weight - 47kg
  • Full Weight - 282kg at the manufacturer’s stated 3-bar condition
  • Published Heat-Up Time - 81 minutes at 9kW under manufacturer test conditions
  • Standing Heat Loss - 1.61kWh per 24 hours under test conditions
  • Operating Pressure - 3 bar
  • Minimum Recommended Incoming Supply - 1.5 bar and 20 litres per minute
  • Maximum Incoming Pressure to Supplied Inlet Controls - 16 bar
  • Water Connections - 22mm compression / ¾-inch BSP
  • Immersion Controls - Individual thermostats and thermal cut-outs
  • Factory Thermostat Setting - 60°C
  • Temperature and Pressure Relief Valve - Factory fitted
  • Country of Manufacture - UK
FAQ's

What is the Megaflo Eco 250DDD?

It is a nominal 250-litre direct unvented hot water cylinder, heated electrically by three immersion heaters. The manufacturer product code is 95050471.

Does this cylinder need a boiler?

No boiler-fed heating coil is used to heat this direct model. Its heat comes from the electric immersion heaters.

What is the difference between a direct and indirect cylinder?

A direct cylinder heats water using electric immersion heaters. An indirect cylinder normally receives heat through a coil connected to a separate heat source, such as a suitable boiler.

What does DDD identify on this model?

The 250DDD is the three-immersion version. The manufacturer specifies three 3kW elements, giving a combined rating of 9kW at 240V.

How does it differ from the Megaflo Eco 250DD?

The 250DD has two 3kW immersion heaters; the 250DDD has three. The additional element increases the available heating input when all elements are energised.

Is this a 3kW or 9kW cylinder?

Each immersion heater is rated at 3kW at 240V. With all three energised, the combined rating is 9kW. It should not be described as a single 9kW element.

Does it always draw 9kW?

No. Consumption depends on which elements are energised and whether their thermostats are calling for heat. The 9kW figure is the combined rated input at 240V.

How long does it take to heat up?

The manufacturer publishes 81 minutes at 9kW under its test conditions. This assumes the full heating input is available; it is not a guaranteed time with only one element operating.

Are the immersion heaters individually controlled?

Yes. The installation manual states that each immersion heater has its own thermostatic control and thermal cut-out.

Can all three heaters be connected to one ordinary 13A plug?

No. The combined 9kW load is not suitable for an ordinary 13A plug connection. A competent electrician must design the supplies, protection, isolation and controls.

Does it need a separate expansion vessel?

The cylinder’s own hot water expansion is accommodated by its internal air gap and floating baffle. The installer must still assess any additional expansion requirements elsewhere in the installation.

Does the internal air gap require maintenance?

It forms part of the system’s inspection and maintenance requirements. A competent service engineer should check the expansion arrangement in accordance with the manufacturer’s instructions.

Will it increase poor incoming mains pressure?

No. Its performance depends on the incoming water supply. The manufacturer recommends assessing pressure, flow and maximum demand before installation.

What incoming pressure and flow are recommended?

The manual recommends at least 1.5 bar and 20 litres per minute. It also warns that these minimum values may provide poor performance if several outlets are used simultaneously.

Can it supply more than one hot water outlet?

It can serve a domestic hot water distribution system, but simultaneous performance depends on supply flow, pipework, stored water and demand. Capacity alone does not guarantee a particular number of showers.