{"product_id":"timeguard-tx2440c-40a-30ma-solid-neutral-rcbo-c-curve-6ka-30ma-type-a-uni-directional","title":"Timeguard TX2440C 40A 30mA Solid Neutral RCBO C Curve 6kA, 30mA Type A, Uni-Directional","description":"\u003cp\u003eTimeguard TX2440C 40A 30mA Type A RCBO – C-Curve, 6kA\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTimeguard TX2440C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40A, 30mA Type A RCBO\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eC-curve overcurrent characteristic\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e6kA breaking capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. It combines overload, short-circuit and residual-current protection for an individual circuit in a compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTimeguard TX series consumer unit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis is the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esolid-neutral, unidirectional version\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Check the complete model specification when ordering a replacement, because other Timeguard 40A RCBOs have different tripping, neutral-switching and power-flow arrangements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eConfirm the three important model details\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eC-curve:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e a higher instantaneous magnetic operating threshold than an equivalent B-curve device. Selection must account for equipment starting currents and the circuit’s fault-protection requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSolid neutral:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e the neutral remains connected when the protected line pole opens.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eUnidirectional:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e the supply and load connections must follow the manufacturer’s markings. This model must not be selected for a circuit requiring bidirectional power flow.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe electrician must also confirm cable protection, consumer unit compatibility and the required isolation arrangement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eType A protection explained\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40A rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e relates to the circuit’s overcurrent protection. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e30mA rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is the rated residual operating current of the earth-leakage protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eType A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e residual-current protection responds to sinusoidal AC and pulsating DC residual currents. It describes a separate function from the C-curve overcurrent characteristic.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCompact dimensions and clearly specified terminals\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe single-module housing measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e18mm wide × 85mm high × 73mm deep\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and mounts onto a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e35mm DIN rail\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTop terminals accept conductors up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10mm²\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with a specified tightening torque of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1.2Nm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Bottom terminals accept up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e25mm²\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with a tightening torque of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2.5Nm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Terminal blanking plates help prevent incorrect cable or busbar insertion.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA test button and contact position indicator are included. The RCBO can also be removed without removing the busbar once the assembly has been safely isolated.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTimeguard provides a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efive-year guarantee\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, subject to its applicable terms. Manufacturer compatibility is limited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTimeguard TX series consumer units\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Timeguard","offers":[{"title":"Default Title","offer_id":57739270127991,"sku":"TX2440C","price":11.16,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0687\/8927\/2802\/files\/electrician-checking-40a-c-curve-type-a-rcbo-for-domestic-consumer-unit-replacement.webp?v=1794473263","url":"https:\/\/www.electricalsonline.co.uk\/products\/timeguard-tx2440c-40a-30ma-solid-neutral-rcbo-c-curve-6ka-30ma-type-a-uni-directional","provider":"Electricals Online","version":"1.0","type":"link"}