{"product_id":"timeguard-tx2406-6a-30ma-solid-neutral-rcbo-b-curve-6ka-30ma-type-a-uni-directional","title":"Timeguard TX2406 6A 30mA Solid Neutral RCBO B Curve 6kA, 30mA Type A, Uni-Directional","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTimeguard TX2406 6A 30mA Type A RCBO\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e combines overload, short-circuit and residual-current protection in one compact device. Designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTimeguard TX series consumer units\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, it provides protection for an individual circuit within a single-module housing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e6A current rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eB-curve characteristic\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e30mA residual-current sensitivity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e perform different roles. The 6A rating forms part of the circuit’s overcurrent protection, while the residual-current function detects an imbalance between the current flowing through the line and neutral conductors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eType A protection explained\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Type A classification means the residual-current function responds to sinusoidal AC and pulsating DC residual currents. This is separate from the B-curve characteristic, which describes the breaker’s response to a high overcurrent.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe circuit’s connected equipment, cable protection and installation requirements must all be considered when selecting the device.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eSolid neutral and unidirectional operation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis model has a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esolid neutral\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, meaning the neutral remains connected when the protected line pole opens. It should therefore be distinguished from a switched-neutral RCBO.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt is also \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eunidirectional\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Supply and load connections must follow the manufacturer’s markings, and the device must not be selected for a circuit requiring bidirectional power flow.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDifferent terminal capacities and tightening torques\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe top terminals accept conductors up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10mm²\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with a specified tightening torque of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1.2Nm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The bottom terminals accept up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e25mm²\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with a tightening torque of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2.5Nm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTerminal blanking plates help prevent incorrect cable or busbar insertion. A contact position indicator and test button are included, and the device can be removed without removing the busbar once the assembly has been safely isolated.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e18mm wide × 85mm high × 73mm deep\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the RCBO mounts onto a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e35mm DIN rail\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Timeguard provides a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efive-year guarantee\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, subject to its applicable terms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer compatibility is limited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTimeguard TX series consumer units\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Timeguard","offers":[{"title":"Default Title","offer_id":57736642527607,"sku":"TX2406","price":11.16,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0687\/8927\/2802\/files\/timeguard-tx-series-tx2406-6a-30ma-type-a-b-curve-solid-neutral-rcbo-front-view.webp?v=1794400188","url":"https:\/\/www.electricalsonline.co.uk\/products\/timeguard-tx2406-6a-30ma-solid-neutral-rcbo-b-curve-6ka-30ma-type-a-uni-directional","provider":"Electricals Online","version":"1.0","type":"link"}